This troubleshooting guide lists all the errors and warning messages from GridLAB-D. Simply search for your message and follow the recommendations given. Last updated Thu Oct 18 04:30:43 PDT 2018.

Warnings | Errors | Fatal errors | Exceptions

Warnings

' \ A B C D E F G H I J L M N O P R S T U V W Z

'string' ('string':'integer') is triplex but doesn't have phases S set

'string' ('string':'integer') parent 'string' ('string':'integer') does not export attach_enduse function so voltage response cannot be modeled

'string' (auction:'integer') capacity_reference_property 'string' is not a double type property

'string' (id:'integer') already has a link parented - this could give invalid answers in FBS!

'string' (id:'integer') is parented to a node, but has a link running into it!

'string' does not have a phase A to fault!

'string' does not have a phase B to fault!

'string' does not have a phase C to fault!

'string'('integer'): libraries not yet supported

'string'('integer'): timezone 'string' is not defined

'string'('integer'): variable 'string' not found

'string': controller price curve is not injective and may behave strangely

'string': The transformer has reached its operational lifespan. Resetting transformer lifetime parameters.

\'design_cooling_capacity\' not specified in parent ~ default to 5 ton or 60,000 Btu/hr

Afflicted object count went negative - using after fault count

Afflicted secondary object count went negative - using after fault count

All values in auction statistic calculations were skipped. Setting mean to zero.

Automatic controls can oscillate to the iteration limit with no time delays. To prevent this, ensure your switching limits are reasonable.

Battery attempted to discharge too far!

Battery SOC calculation messed up and somehow went outsize 0 - 100 range!

battery:'integer' 'string' - Deltamode is enabled for the module, but not this generator!

battery:'string' indicates it wants to run deltamode, but the module-level flag is not set!

bid_delay was less than the current minimum_timestep setting - rounded up to one whole timestep

Capacitance calculation failure for 'string'

Capacitor 'string' has no pt_phase set, volt_var_control 'string' will pick the first phases_connected

Capacitor:'integer' - 'string' - the remote_sense object is a network_interface, node/link connections both enabled

Capacitor:'integer' does not have its upper voltage limit set.

Capacitor:'integer' does not have one or both of its current set points set.

Capacitor:'integer' does not have one or both of its VAr set points set.

Capacitor:'integer' does not have one or both of its voltage set points set.

Capacitor:'integer' has a secondary sensor specified, but is not in VARVOLT control. This will be ignored.

Capacitor:'integer' is set to manual bank mode, but does not know which phase to monitor.

class_define_map(oclass='string',...): class 'string' does not assert UNSAFE_OVERRIDE_OMIT when parent class 'string' does

class_define_map(oclass='string',...): class 'string' suppresses parent class 'string' BOTTOMUP sync behavior by omitting override

class_define_map(oclass='string',...): class 'string' suppresses parent class 'string' POSTTOPDOWN sync behavior by omitting override

class_define_map(oclass='string',...): class 'string' suppresses parent class 'string' PRETOPDOWN sync behavior by omitting override

class_find_property(CLASS *oclass='string', PROPERTYNAME name='string': property is deprecated

climate:'string' - Southern hemisphere solar position model may have issues

compare of strings using numeric op usually does not work

continuous_rating for link:'string' is zero - this may lead to odd warning messages about line limits with nonsense values

DC maximum power output is less than the real power output from the inverter. A higher DC power rating is recommended. Currently the VSI power output is not limited by the DC power output.

debugger.conf was not found

diesel_dg:'integer' 'string' - cannot set both Kd1 and Kd2 as 0 for the CVR conntrol! Have changed Kd2 to be 1

diesel_dg:'integer' 'string' - Deltamode is enabled for the module, but not this generator!

diesel_dg:'integer' 'string' - overload_limit has a value less than or equal to zero - set to 1.25

diesel_dg:'integer' - 'string' has no parent object - default voltages being used

diesel_dg:'string' - power_out_A is above 1/3 the total rating, capping

diesel_dg:'string' - power_out_A is zero - arbitrarily setting to 50%%

diesel_dg:'string' - power_out_B is above 1/3 the total rating, capping

diesel_dg:'string' - power_out_B is zero - arbitrarily setting to 50%%

diesel_dg:'string' - power_out_C is above 1/3 the total rating, capping

diesel_dg:'string' - power_out_C is zero - arbitrarily setting to 50%%

diesel_dg:'string' - rotor_speed_convergence is less than zero - negating

diesel_dg:'string' - rotor_speed_convergence is zero - it may never exit deltamode!

diesel_dg:'string' - voltage convergence is enabled, but no exciter is present

diesel_dg:'string' - voltage_convergence is less than zero - negating

diesel_dg:'string' - voltage_convergence is zero - it may never exit deltamode!

diesel_dg:'string' did not have a valid Rated_V set, assuming 15 kV

diesel_dg:'string' did not have a valid Rated_VA set, assuming 10 MVA

diesel_dg:'string' did not have a valid Rated_VA set, assuming 5000 kVA

diesel_dg:'string' forced into DYN_SYNCHRONOUS mode

diesel_dg:'string' indicates it wants to run deltamode, but the module-level flag is not set!

Efficiency unspecified - defaulted to 'real' for this inverter type

emergency_rating for link:'string' is zero - this may lead to odd warning messages about line limits with nonsense values

Empty powerflow connectivity matrix for island 'integer', your system is empty!

Empty powerflow connectivity matrix, your system is empty!

evcharger_det:'string' - the breaker rating may be too low for this maximum charge rate.

evcharger_det:'string' - The max charge rate is over 1.7 kW (Level 1), but the load is still 110-V connected.

event_gen:'string' does not have a metrics object as a parent -- metrics are not calculated.

event_gen:'string' has the ability to generate more than 1 simultaneous fault - metrics may not be accurate

eventgen:'string' - minimum_timestep set - all events at least 1 minimum step long

eventgen:'string' indicates it wants to run deltamode, but the module-level flag is not set!

Eventgen:'string' is flagged for deltamode, but reliability deltamode is not enabled

explicit 'string' model is experimental

explicit 'string' model is experimental and has not been validated

Failure to load solver_'string' as a library, defaulting to superLU

Failure to map deltamode function for device:'string'

Failure to map deltamode saturation function for device:'string'

Failure to map VFD current injection update for device:'string'

fault_check interaction with restoration requires meshed checking mode - enabling this now

fault_check:'string' was forced into meshed search mode due to multiple grids being desired

file 'string' ignored in test mode

Fuse status updated, but no other changes made.

Fuse:'string' fuse_resistance has been set to zero. This will result singular matrix. Setting to the global default.

Fuse:'string' has a negative or 0 mean replacement time - defaulting to 1 hour

fuse:'string' has a zero current limit - set to 9999.9 Amps

Fuses only work for the attached node in the FBS solver, not any deeper.

generator_controller:'string' entered an unexpected state - results may be invalid!

Generator_rating and bid_generator_rating both have values in generator_controller:'string'

global_create(char *name='string',...): property 'string' unit 'string' is not recognized

gridlabd.conf was not found

group_recorder::init(): no filename defined, auto-generating 'string'

group_recorder::init(): unable to open file 'string' for writing

house_e:'integer' 'string' - Deltamode is enabled for the module, but not this house!

house_e:'string' indicates it wants to run deltamode, but the module-level flag is not set!

impedance1 was defined, but impedance2 was not -- assuming they are equal

impedance2 was defined, but impedance1 was not -- assuming they are equal

Infinite reconfiguration iterations set.

Init() triplex_node (name:'string', id:'integer'): Phases specified did not include phase S. Adding phase S.

init(): Rated_kVA or {area or rated insolation or effiency} were not specified or specified as zero. Leads to maximum power output of 0.

init(): Rated_kVA, efficiency, Rate_Insolation, and area did not calculated to the same value. Ignoring Rated_kVA.

init: object 'string':'integer' should have a name, but doesn't

INIT: overhead_line:'string' has a negative resistance in it's impedance matrix. This will result in unusual behavior. Please check the line's geometry and cable parameters.

INIT: triplex_line:'string' has a negative resistance in it's impedance matrix. This will result in unusual behavior. Please check the line's geometry and cable parameters.

INIT: underground_line:'string' has a negative resistance in it's impedance matrix. This will result in unusual behavior. Please check the line's geometry and cable parameters.

Invalid derating factor specified, defaulting to 95%%

Invalid soiling factor specified, defaulting to 95%%

inverter:'integer' 'string' - Deltamode is enabled for the module, but not this inverter!

Inverter:'integer' 'string' does not have a valid parent - 1547 checks have been disabled

Inverter:'integer' has no parent meter object defined; using static voltages

inverter:'integer'-'string' - IEEE 1547 checks are enabled, but the model is not deltamode-enabled

inverter:'string' - a short pf_reg_activate_lockout_time may lead to inverter controller oscillations. Recommended time: > 60s

inverter:'string' - battery at or below the SOC reserve - no discharging allowed

inverter:'string' - battery full - no charging allowed

inverter:'string' - charge_lockout_time is zero, oscillations may occur

inverter:'string' - charge_on_threshold and charge_off_threshold are equal - may not behave properly!

inverter:'string' - discharge_lockout_time is zero, oscillations may occur

inverter:'string' - discharge_off_threshold should be larger than the charge_off_threshold

inverter:'string' - discharge_on_threshold and discharge_off_threshold are equal - may not behave properly!

inverter:'string' - max_charge_rate is zero

inverter:'string' - max_discharge_rate is zero

inverter:'string' - pf_reg_activate_lockout_time is unassigned, using default value of 60s.

inverter:'string' - pf_reg_activate_lockout_time is zero, oscillations may occur

inverter:'string' - pf_reg_high is undefined, setting to a default value of -0.95

inverter:'string' - pf_reg_low is undefined, setting to a default value of 0.97

inverter:'string' - pf_target_var is undefined, setting to a default value of 0.95

inverter:'string' - sense_object not specified for LOAD_FOLLOWING and/or power-factor regulation - attempting to use parent object

inverter:'string' indicates it wants to run deltamode, but the module-level flag is not set!

inverter:'string' is LOAD_FOLLOWING and/or power-factor regulating based on a meter or triplex_meter, ensure the inverter is connected inline with that object!

jsondump:'integer'-'string' -- If per-unit impedance is desired, a valid system_base must be specified - defaulting to 100 MVA

lighting load 'real' exceeds installed capacity

lights load 'real' is negative

Line:'string' is at 'real'%% of its continuous rating on phase 1!

Line:'string' is at 'real'%% of its continuous rating on phase 2!

Line:'string' is at 'real'%% of its continuous rating on phase A!

Line:'string' is at 'real'%% of its continuous rating on phase B!

Line:'string' is at 'real'%% of its continuous rating on phase C!

Line:'string' is at 'real'%% of its emergency rating on phase 1!

Line:'string' is at 'real'%% of its emergency rating on phase 2!

Line:'string' is at 'real'%% of its emergency rating on phase A!

Line:'string' is at 'real'%% of its emergency rating on phase B!

Line:'string' is at 'real'%% of its emergency rating on phase C!

link:'integer' - 'string' -- fault current not available on very first time loop

link:'string' has a negative mean_repair_time, set to 1 hour

load:'string' - constant_current loads in deltamode are handled slightly different

load:'string' - ZIP components on phase 'character' did not sum to 1. Setting power_fraction to 'real'

load:'string' - ZIP components on phase 1 did not sum to 1. Setting power_fraction to 'real'

load:'string' - ZIP components on phase 12 did not sum to 1. Setting power_fraction to 'real'

load:'string' - ZIP components on phase 2 did not sum to 1. Setting power_fraction to 'real'

locale pop failed

locale TZ is empty

LU_init of external solver solver_'string' not found, defaulting to superLU

Manual event 'integer' of eventgen:'string' exceeded the simultaneous fault limit and was ignored

market statistic 'string' interval not a multiple of market period, rounding towards one interval

market statistic 'string' samples faster than the market updates and will be filled with immediate data

market statistic interval for 'string' is not positive, skipping

Maximum outage for 'string' was above global max - restricted to global max

metrics_collector_writer::init(): no filename defined, auto-generating 'string'

motor:'string' -- both H and J were specified, H will be used, J is ignored

NHTS data file not found, using defaults

No battery objects were found, but the VSI object exists. Now assume the VSI is attached with infinite input power.

No capacitor phase connection information is available for capacitor:'integer'. Defaulting to the phases property.

No climate data found - using static temperature

No eventgen object mapped up to 'string', unscheduled faults are not allowed

No fault_check object present - Newton-Raphson solver may fail!

No link objects were found.

No lockout time specified for capacitor:'integer's VAR-VOLT control scheme. May switch excessively.

No value for bid_gen_rating set, assuming $0.0 Op and Maint cost

node:'integer' - 'string' - Attempted to map an NR-based function, but is not using an NR solver

node:'integer' - 'string' - Tried to re-enable a node that wasn't disabled!

node:'string' - Not a SWING-capable bus, so no swing status swap changed

Node:'string' does not have the same nominal voltage as its parent - copying voltage from parent.

node:'string' has a negative mean_repair_time, set to 1 hour

Node:'string' is parented to a swing node and will get folded into it.

NR: A matrix dump was requested, but no filename was specified. No dump will occur

Object 'string' (node:'integer') is flagged for deltamode, but it's parent is not. This may lead to incorrect answers!

Only WYE-WYE configurations are working in either Newton-Raphson or non-Manual controls

outage length for object:'string' in eventgen:'string' exceeds the defined maximum outage.

Outage length for object:'string' is less than the minimum timestep of 'real' seconds, rounded to minimum timestep

Phase A of fuse:'string' just blew!

Phase B of fuse:'string' just blew!

Phase C of fuse:'string' just blew!

power_convergence_value not set - defaulting to 0.01 base_power

property_malloc(oclass='string',...): property name 'string' is defined more than once

pw_load::init(): power_threshold is negative, making positive

pw_load::init(): power_threshold is zero, convergence may not occur!

pw_load::init(): power_threshold was zero, set to 0.1%% of load - 'real' MVA

random_bernoulli(p='real'): p is not between 0 and 1

random_bernoulli(p='real'): p is not within the normal bounds of +/-1e(+/-30)

random_degenerate(a='real'): a is outside normal bounds of +/-1e(+/-30)

random_exponential(l='real'): l is not within the normal bounds of 1e(+/-30)

random_normal(m='real', s='real'): s is negative

random_pareto(m='real', k='real'): k is not within the normal bounds of +/-1e(+/-30)

random_pareto(m='real', k='real'): m is not within the normal bounds of +/-1e(+/-30)

random_sampled(n='integer',...): sampled value is not within normal bounds of +/-1e(+/-30)

random_uniform(a='real', b='real'): a is outside normal bounds of +/-1e(+/-30)

random_uniform(a='real', b='real'): b is less than a

random_uniform(a='real', b='real'): b is outside normal bounds of +/-1e(+/-30)

range:'integer' is using an experimental model and should not be considered reliable

Regulator 'string' has phase 'character' at the maximum tap value

Regulator 'string' has phase 'character' at the minimum tap value

Regulator:'string' regulator_resistance has been set to zero. This will result singular matrix. Setting to the global default.

Restoration object not detected!

restoration: Attempt to parse complex CSV array resulted in an empty array - check your inputs

restoration: Attempt to parse double CSV array resulted in an empty array - check your inputs

restoration: Attempt to parse object CSV array resulted in an empty array - check your inputs

restoration: The source vertex for the reconfiguration is not defined, defaulting to a swing bus

Reverse real power flow detected at generator switch 'string', generator is absorbing real power now!

ron or roff was not set. Using phi to calculate. Step changes in demand rates as a function of time will be ignored.

ron or roff was not set. Using phi to calculate. Step changes in demand rates as a function of time will be ignored.

Shunt capacitance of overhead line:'string' not calculated - invalid values

Solar object:'string' is in player mode - be sure to specify relevant values

solar:'integer' 'string' - Deltamode is enabled for the module, but not this solar array!

solar:'string' - Default solar position model is not recommended for southern hemisphere!

solar:'string' indicates it wants to run deltamode, but the module-level flag is not set!

solarpanel: 'integer' climates found, using first one defined

solarpanel: no climate data found, using static data

stored_capacity and SOC are both defined, SOC being used for initial energy state

substation attached to pw_load and not a SWING bus - forcing to SWING

substation is not a SWING bus, so answers may be unexpected

substation:'string' is set up as a normal node, no sequence values will be calculated

SWING bus:'string' is not flagged for deltamode

switch objects may not behave properly under FBS!

Switch status updated, but no other changes made.

Switch:'string' switch_resistance has been set to zero. This will result singular matrix. Setting to the global default.

The dc voltage is greater than the specified maximum for the inverter. Efficiency model may be inaccurate.

The external solver solver_'string' could not be found, defaulting to superLU

The generator has already exhausted its yearly runtime quota, it will not run this year

The PV is over rated for its parent inverter.

This connection type on transformer:'integer' ('string') does not support impedance (impedance1 or impedance2) of secondaries at this time.

This connection type on transformer:'integer' ('string') does not support shunt_impedance at this time.

transformer:'integer' 'string' is set to model saturation, but has no magnetization location

transformer:'string' is at 'real'%% of its rated power value

transormer_configuration:'integer' ('string') reactance_resistance_ratio was not set and defaulted to 4.5. This may cause issues with larger transformers (>0.5 MVA)

triplex_load:'string' - constant_current loads in deltamode are handled slightly different

Unable to compute capacitance for 'string'

Unable to find secondary interruption flag, no secondary interruptions recorded in metrics:'string'

Unable to map add_event function in eventgen:'string'

Unable to map mean_repair_time from object:'string'

Underground_line:'integer' 'string' - phase N conductor should just be a normal conductor!

Underground_line:'integer' - 'string' is a tape-shielded cable and may need an explicit phase N conductor

Unsupported phase on a possibly meshed node

Unsupported phase on node 'string'

Vehicle location not set, using defaults

VFD:'integer' - 'string' - FROM node nominal_voltage is not equal to or greater than TO node nominal_voltage - implies DC-DC converter!e

VFD:'integer' - 'string' - nominal_output_frequency is not set or is negative - defaulting to system nominal

VFD:'integer' - 'string' - rated_output_voltage does not match the TO node nominal voltage

VFD:'integer' - 'string' - rated_output_voltage was not set, defaulting to TO node nominal

VFD:'integer' - 'string' - the desired_motor_speed results in a frequency of less than 3.0 Hz

VFD:'integer' - 'string' - VFD currently at 'real'%% of rated speed -- VFDs perform best when running at >= 75 percent output

volt_var_control 'string': A link to monitor power-factor was not specified, using first regulator.

volt_var_control 'string': capacitor_delay should be greater than or equal to 1 to prevent convergence issues.

volt_var_control 'string': Desired, minimum, and maximum voltages don't match

volt_var_control 'string': Low loading deadband for regulator 'integer' is expected to be larger than the high loading deadband

volt_var_control 'string': No capacitors specified.

volt_var_control 'string': No measurement point specified for reg 'integer' - defaulting to load side of regulator

volt_var_control 'string': Power factor monitored phases not set - defaulting to substation_link phases

volt_var_control 'string': regulator_delay should be greater than or equal to 1 to prevent convergence issues.

volt_var_control 'string': The set point for phase A will exceed the maximum allowed voltage!

volt_var_control 'string': The set point for phase A will exceed the minimum allowed voltage!

volt_var_control 'string': VDrop, low V BW, and high V BW don't match

waterheater:'integer' is boiling

windturb_dg (id:'integer', name:'string'): Rated generator voltage (LL: 'real') and nominal voltage (LL: 'real') of meter parent are different by greater than 10 percent. Odd behavior may occur.

windturb_dg (id:'integer',name:'string'): internal iteration limit reached, breaking out of loop. Injected current may not be solved sufficiently.

zipload_init: The demand response zipload is an experimental model at this time.

zipload_init: Using a value for thermostatic_control_range (L) greater than 50 may cause some instabilities.


Warnings | Errors | Fatal errors | Exceptions

Errors

' A B C D E F G H I L M N O P R S T U V W

'string' (auction:'integer') capacity_reference_object of type 'string' does not contain specified reference property 'string'

'string' (auction:'integer') capacity_reference_object specified without a reference property

'string' (auction:'integer') is using a one-sided market with a negative fixed quantity

'string' is an invalid nsync command

'string' is an invalid option to details command

'string' is an invalid option to inactive command

'string' is an invalid option to unnamed command

'string' is not a recognized breakpoint subcommand

'string' is not recognized

'string': 'string' (GLPATH='string')

'string': object 'string' stopped its clock (debug)!

'string': object 'string' stopped its clock (exec)!

'string': object 'string' stopped its clock! (test)

'string': set_rank internal error, rank > object count

'string': target 'string' is not valid

'string': transformer configuration installed insulation life must be greater than zero

'string': transformer granularity is too small for the minimum timestep specified

'string'::'string'.create(OBJECT **obj={name='string', id='integer'},...): 'string'

'string'::'string'.init(OBJECT **obj={name='string', id='integer'},TIMESTAMP t1='string'): 'string'

'string'::'string'.init(OBJECT *obj={name='string', id='integer'}): 'string'

'include' variable is not set and neither is GRIDLABD environment, compiler cannot proceed without a way to find gridlabd.h

access to global process map 'string' is denied

aggregate group 'string' does not use a known aggregator

aggregate group 'string' has invalid units ('string')

aggregate group 'string' is not valid

aggregate group expression 'string' does not result in a set with a fixed class

aggregate group expression 'string' does not result is a usable object list

aggregate group expression 'string' failed

aggregate group expression 'string' results is an empty object list

aggregate group property 'string' cannot be aggregated

aggregate group property 'string' cannot have part 'string'

aggregate group property 'string' cannot use units 'string'

aggregate group property 'string' is not found in the objects satisfying search criteria 'string'

aggregate group property 'string' is unitless and cannot be converted

Although controller given group id, no dgs with given group id found.

An error occured writing the CLSID to the registry.

An object named 'string' already exists!

auction init_stdev is negative!

bidding into future markets is not yet supported

Capacitor:'integer' does not have any capacitance values defined!

check_COM_output: 'string'

check_COM_output: bad index in SafeArrayGetElement

check_COM_output: COM call did not return an array of variants

check_COM_output: invalid arguement in SafeArrayGetElement

check_COM_output: ran out of memory during SafeArrayGetElement

check_COM_output_load: 'string'

check_COM_output_load: bad index in SafeArrayGetElement

check_COM_output_load: COM call did not return an array of variants

check_COM_output_load: invalid arguement in SafeArrayGetElement

check_COM_output_load: ran out of memory during SafeArrayGetElement

class 'string' not found

class_define_function(CLASS *class={name='string',...}, FUNCTIONNAME functionname='string', ...) the function name has already been defined

class_define_map(oclass='string',...): expected keyword missing after 'string'

class_define_map(oclass='string',...): parent property class name 'string' attempting to inherit from self!

class_define_map(oclass='string',...): parent property class name 'string' is not defined

class_define_map(oclass='string',...): property 'string' unit 'string' is not recognized: 'string'

class_define_map(oclass='string',...): property keyword 'string' could not be defined as value 'integer'

class_define_map(oclass='string',...): property name 'string' conflicts with built-in property

class_define_map(oclass='string',...): property name 'string' is too big

class_define_map(oclass='string',...): property size must be greater than 0

class_define_map(oclass='string',...): PT_INHERIT unexpected; class already inherits properties from class 'string'

class_define_map(oclass='string',...): substructure of property 'string' substructure could not be published

class_define_map(oclass='string',...): unrecognized extended property (PROPERTYTYPE='string')

class_define_map(oclass='string',...): unrecognized property access code (value='integer' is not valid)

class_find_property(oclass='string', name='string') causes an infinite class inheritance loop

class_find_property_rec(CLASS *oclass='string', PROPERTYNAME name='string', CLASS *pclass='string') causes an infinite class inheritance loop

climate:'string' - Latitude is outside +/-90!

climate:'string' - Longitude is outside +/-180!

climate::init(): no csv_reader specified for tmyfile 'string'

CloseCase() failed

code_block malloc failed (inline_block_size='integer')

command line option 'string' is not recognized

commit_all() failure: 'string'

compare op 'integer' not supported on doubles

compare op 'integer' not supported on integers

compare op 'integer' not supported on strings

comparison operators not supported for property type 'string'

compound unit 'string' could not be correctly identified

connection::preupdate: deltamode_timestep must be a positive, non-zero number!

convergence iteration limit reached at 'string' (exec)

convergence iteration limit reached for object 'string' (debug)

convergence iteration limit reached for object 'string':'integer'

convergence iteration limit reached for object 'string':'integer' (test)

convert_from_complex(): unable to convert unit 'string' to 'string' for property 'string' (tape experiment error)

convert_to_complex('string','string'): complex number format is not valid

convert_to_double(const char *buffer='string', void *data=0x%*p, PROPERTY *prop={name='string',...}): unit conversion failed

could not find 'from' unit 'string' for unit_convert

could not find 'to' unit 'string' for unit_convert

could not run unit_convert_complex due to null arguement

could not run unit_convert_ex due to null arguement

csv_reader could not open \'string'\' for input!

csv_reader has no input file name!

csv_reader::read_header ~ unable to find column property \'string'\'

csv_reader::read_line ~ unable to read time string \'string'\' with default format

csv_reader::read_line ~ unable to read time string \'string'\' with format \'string'\'

csv_reader::read_line ~ unable to set value \'string'\' to double property \'string'\'

csv_reader::read_prop ~ error reading property & value

csv_reader::read_prop ~ missing \'=\' seperator

csv_reader::read_prop ~ unable to convert property \'string'\' due to type restrictions

csv_reader::read_prop ~ unable to set property \'string'\' to \'string'\'

csv_reader::read_prop ~ unrecognized csv_reader property \'string'\'

delegated types not supported using class_define_type (use class_define_map instead)

delta mode initialization failed

delta_preupdate(): module 'string' failed

delta_update() failed, deltamode operation cannot continue

delta_update(): clockupdate failed

delta_update(): delta_interupdate() wanted to exit deltamode. However, delta_clockupdate() wanted to continue in deltamode. This shouldn't happen. Please check your object's delta_clockupdate function to determine what went wrong.

delta_update(): delta_interupdate() wanted to move to the next deltamode timestep. However, delta_clockupdate() wanted to exit deltamode. This shouldn't happen. Please check your object's delta_clockupdate function to determine what went wrong.

delta_update(): interupdate failed

delta_update(): interupdate federation iteration limit reached

delta_update(): interupdate iteration limit reached

delta_update(): postupdate failed

delta_update(): preupdate failed

delta_update(): update failed for object \'string'\'

deltamode player: player \

details command syntax error

diesel_dg: failed to allocate to allocate the delayed torque array for Governor!

diesel_dg: failed to allocate to allocate the delayed x5a array for Governor!

dump to 'string' failed

Error from GetParametersSingleElement(): 'string'

Error from SetParametersSingleElement(): 'string'

exec_add_breakpoint() - memory allocation failed

exec_add_watchpoint() - memory allocation failed

expression(): invalid find op!

Failed to allocate battery array.

Failed to allocate inverter array.

Failed to allocate solar array.

Failed to perform postupdate for group_recorder object

Failed to swap SWING status of node:'string' on inverter:'string'

fault_check:'integer' 'string' -- Special debug mode utilized, simulation terminating

federation convergence iteration limit reached at 'string' (exec)

finalize_all() failure: 'string'

find expression on 'string' not supported

find expression refers to unknown or unsupported property 'string'

findtype 'string' not supported

Generator deltamode update - failed to link to powerflow frequency

Generator object:'string' - deltamode function returned an error!

Generator object:'string' - failed post-deltamode update

generators::deltamode_timestep must be a positive, non-zero number!

get_market_for_time() was called with a null object pointer

global variable definition 'string' not formatted correctedly

global_block malloc failed (inline_block_size='integer')

global_init(): global variable 'string' registration failed

global_setvar(): unable to set 'string' to 'string'

global_setvar(char *name='string',...): value is too long to store

group_recorder::commit(): the object has error'ed and is halting the simulation

group_recorder::flush_line(): output file is not open

group_recorder::flush_line(): unable to flush output file

group_recorder::init(): an error occured when writing the file header

group_recorder::init(): invalid write_interval of 'integer', must be -1 or greater

group_recorder::init(): no group defined

group_recorder::init(): the defined group returned an empty set

group_recorder::init(): unable to construct a set with group definition

group_recorder::init(): unable to find property 'string' in an object of type 'string'

group_recorder::read_line(): malloc failure

group_recorder::read_line(): potential buffer overflow from a too-short automatically sized output value buffer

group_recorder::read_line(): unable to get complex property 'string' from object 'string'

group_recorder::read_line(): unable to get value for 'string' in object 'string'

group_recorder::sync

group_recorder::sync(): error when writing the values to the file

group_recorder::write_footer(): output file is not open

group_recorder::write_header(): the output file was not opened

group_recorder::write_line(): error when converting the sync time

group_recorder::write_line(): error when writing the sync time as a string

group_recorder::write_line(): error when writing to the output file

group_recorder::write_line(): no output file open and state is 'open'

group_recorder::write_line(): output buffer not initialized (read_line() not called)

House thermal mass or UA invalid. Eigen values not set.

house: thermostat setpoints deadbands overlap (TcoolOff='real' < TheatOff='real')

house:'integer' 'string'; using static voltages

house:'integer' - 'string' - Failed to map powerflow variable

ignored signal 'integer'

inactive command syntax error

init failure: 'string'

init(): Rated Insolation was not specified (or zero). Power outputs cannot be calculated without a rated insolation value.

init_all(): object 'string' initialization failed

init_block malloc failed (inline_block_size='integer')

instance_cnx_mmap: no instance provided

invalid breakpoint number

invalid debug command, try 'help'

invalid debug state

invalid findtype means search is specified incorrectly or FT_END is probably missing

invalid object or value

invalid property for object 'string'

invalid time

invalid watchpoint number

Inverter 1547 Checks - invalid state!

Inverter failed pre_deltaupdate call

Inverter:'integer' 'string' failed to map the nominal_voltage property

inverter:'string' - charge_lockout_time is negative!

inverter:'string' - discharge_lockout_time is negative!

inverter:'string' - inverter failed to map power calculation function of transformer!

inverter:'string' - LOAD_FOLLOWING and power-factor regulation will not work without a specified sense_object!

inverter:'string' - sense_object is a link, but not a transformer!

inverter:'string' - sense_object is a node, but not a meter or triplex_meter!

inverter:'string' - sense_object is not a proper powerflow object!

inverter:'string' -- Failed to find node swing swapper function

Latitude beyond the currently supported range 24 - 48 N, Simulations will continue assuming latitude 'real'N

lights parent must publish \'floor_area\' to work properly if no installed_power is given ~ default 2500 sf

market latency queue is overwriting as-yet unused data, so is not long enough or is not consuming data

maximum number of allowed schedule blocks exceeded

metrics_collector allows only these parents: triplex meter, house, waterheater, inverter, substation, meter, capacitor, regulator

metrics_collector must have a parent (triplex meter, house, waterheater, inverter, substation, or meter)

metrics_collector must have a triplex meter, house, waterheater, inverter, swing-bus, capacitor or regulator as its parent

metrics_collector must have a triplex meter, meter, house, waterheater, inverter or swing-bus as its parent

metrics_collector::init(): invalid interval of 'integer', must be greater than 0

metrics_collector_writer::init(): error when converting the starting time

metrics_collector_writer::init(): error when writing the starting time as a string

metrics_collector_writer::init(): invalid interval of 'integer', must be greater than 0

missing file name for script command

model initialization failed

model_commit_failed

module 'string' cannot register class 'string', it is already registered by module 'string'

module 'string' does not exist

module 'string' load failed - invalid DLL format

module 'string' not found

module 'string' return invalid/infinite dt for delta mode inquiry

module_load(file='string'::'string'): subload failed

mti_init memory allocation failed

Newton-Raphson failed to converge the dynamic powerflow, sticking at same iteration.

Newton-Raphson method is unable to converge the dynamic powerflow to a solution at this operation point

No batteries with inverter parents with given group id found.

No inverters with given group id found.

No line or bus objects were found.

no solars with inverter parents with given group id found.

Node frequency update: unknown state encountered

Node'integer' 'string' GFA checks failed- invalid state!

node:'integer' ('string') has more phases leaving than entering

node:'integer' - 'string' - Already has an extra current injection function mapped

node:'integer' - 'string' - Failed to map current_injection_update from calling object:'integer' - 'string'

node:'integer' - 'string' - Parent node:'integer' - 'string' - Already has an extra current injection function mapped

Nominal voltages of tranmission node ('real' V) and substation ('real') do not match!

NR: 'string' tried to parent to a node that has too many children already

NR: memory allocation failure for branch table

NR: memory allocation failure for bus table

nsync command syntax error

object 'string' does not exist

object 'string' does not have a property named 'string'

object 'string' finalize failed

object 'string' finalize memory allocation failed

object 'string' precommit failed

object 'string' precommit memory allocation failed

object 'string' undefined

object 'string':'integer' called set_header_value() for invalid field 'string'

object 'string':'integer' latitude 'string' is invalid

object 'string':d longitude 'string' is invalid

object 'string':d name already set to 'string'

object dump failed

object id 'integer' not found

occupantload must have a parent house

occupantload parent must publish attach_enduse()

OpenCase() failed

parent 'string' not found

Powerflow object:'integer' - 'string' - deltamode function returned an error!

Powerflow object:'string' - failed post-deltamode update

powerflow::deltamode_timestep must be a positive, non-zero number!

powerworld_bus_num must be a non-negative integer

powerworld_load_id must be set

precommit_all() failure: 'string'

property 'string' of 'string' is cannot be set like an int16

property type 'string' not recognized in enduse_publish

property_malloc(oclass='string',...): memory allocation failed

property_malloc(oclass='string',...): property 'string' cannot have unit 'string' because it is not a double or complex value

PT_KEYWORD not allowed unless it follows another property specification

PT_KEYWORD not supported after property 'string' 'string' in enduse_publish

pw_load::init(): object \'string'\' does not specify a parent model object

pw_load::init(): object \'string'\' specifies a parent object \'string'\' that is not a pw_model object

pw_load::init(): unable to get PowerWorld bus voltage from Bus #'integer', Load ID 'string', for the pw_load \'string'\'

pw_load::init(): unable to get PowerWorld nominal voltage from Bus #'integer', for the pw_load \'string'\'

pw_load::presync(): cModel is null (is deferred initialization enabled?)

pw_load::presync(): get_powerworld_busangle failed

pw_load::presync(): get_powerworld_voltage failed

pw_load::presync(): GPSE failed

pw_model::init(): no PowerWorld model file specified

pw_recorder::build_keys(): 'string' did not parse any key strings

pw_recorder::build_keys(): 'string' did not parse any key values

pw_recorder::build_keys(): 'string' has 'integer' key properties and 'integer' key values listed

pw_recorder::init(): error when building keys for 'string'

pw_recorder::init(): error when calling GetParameterSingleElement wrapper function for 'string'

pw_recorder::init(): invalid interval in 'string'

pw_recorder::init(): key_strings not defined for 'string'

pw_recorder::init(): key_values not defined for 'string'

pw_recorder::init(): model of 'string' is not a pw_model

pw_recorder::init(): object \'string'\' does not specify a model object

pw_recorder::init(): parent of 'string' is not a pw_model

pw_recorder::init(): properties not defined for 'string'

pw_recorder::init(): unable to open outfile 'string' for writing

pw_recorder::init(): unable to write header for 'string'

rank 'string' is invalid

ranks setup failed

received SIGABRT; exiting now

received SIGTERM; exiting now

Reliability object:'integer' - 'string' - deltamode function returned an error!

Residential object:'integer' - 'string' - deltamode function returned an error!

Residential object:'string' - failed post-deltamode update

residential::deltamode_timestep must be a positive, non-zero number!

restoration: Attempting to parse a character token failed

restoration: Attempting to parse a complex character token failed

restoration: Failed to allocate space for complex array!

restoration: Failed to allocate space for double array!

restoration: Failed to allocate space for object array!

RunScriptCommand(EnterMode(RUN);) failed

RunScriptCommand(SolvePowerFlow;) failed

saveall: extension '.'string' not a known format

schedule 'string' has 'integer' gaps which may cause erroneous results

schedule 'string': block 'string' definition is too long

schedule 'string': unexpected text before block start

schedule name is too long

schedule_compile(SCHEDULE *sch='{name='string', ...}') ignored an invalid definition 'string'

schedule_compile(SCHEDULE *sch='{name='string', ...}') maximum number of blocks reached

schedule_compile(SCHEDULE *sch={name='string', ...}) 'string' in block 'string' has a conflict with value 'real' on 'string' 'integer'/'integer' 'integer':'integer'

schedule_compile(SCHEDULE *sch={name='string', ...}) 'string' pattern syntax error in item 'string'

schedule_create(char *name='string', char *definition='string') definition does not match previous definition of schedule 'string')

schedule_create(char *name='string', char *definition='string') definition too long)

schedule_create(char *name='string', char *definition='string') memory allocation failed)

schedule_create(char *name='string', char *definition='string') name too long)

schedule_recompile(SCHEDULE *sch='{name='string', ...}') ignored an invalid definition 'string'

schedule_recompile(SCHEDULE *sch={name='string', ...}) 'string' in block 'string' has a conflict with value 'real' on 'string' 'integer'/'integer' 'integer':'integer'

schedule_recompile(SCHEDULE *sch={name='string', ...}) 'string' pattern syntax error in item 'string'

set syntax error ('integer' items)

shared memory limit exceeded (need 'real'kB)

solver_NR: An attempt to allocate a variable array for the NR solver failed!

solver_NR: Attempted to allocate over an existing NR solver variable array!

solver_nr: Mesh fault impedance extract failed - invalid node

solver_nr: Mesh impedance attempted from unsupported LU solver

solver_nr: Node reference for mesh fault calculation was invalid -- it may be a child

solver_nr: superLU failed mesh fault matrix inversion with code 'integer'

Specified target 'string' for 'string' is not valid.

strdatetime: timestamp larger than provided buffer

strict naming prevents implicit creation of 'string'

substation needs to have all three phases!

tape object:'integer' - unable to allocate space for deltamode

The high window temperature cutoff must be greater than the low window temperature cutoff.

thread memory allocation failed

timestamp_year: the year has rolled over or become negative!

tried to create global variable 'string' a second time

trying to get the private property 'string' in 'string'

trying to read the value of private property 'string' in 'string'

trying to set the value of non-public property 'string' in 'string'

unable to add class breakpoint

unable to add clock breakpoint

unable to add error breakpoint

unable to add module breakpoint

unable to add object breakpoint

unable to add object watchpoint

unable to add pass breakpoint

unable to add rank breakpoint

unable to add timestamp breakpoint

unable to allocate ISimulatorAutoPtr in init()

unable to allocate memory for deltamode module list

unable to allocate memory for deltamode object list

unable to allocate memory for deltamode rankcount

unable to allocate memory for deltamode rankcount 'integer'

unable to allocate memory for deltamode ranklist

unable to convert from delegated property value

unable to create cache 'string' for instance 'string' (error code 'integer')

unable to find clsid \

unable to implicitly create the global variable 'string'

unable to load 'string': 'string'

Unable to map battery parent object as inverter.

Unable to map group_recorder postupdate function

Unable to map object as battery.

Unable to map object as inverter.

Unable to map object as solar.

Unable to map solar parent object as inverter.

unable to open file 'string' for reading

unable to publish enumeration member 'string' of enduse 'string'

unable to publish set member 'string' of enduse 'string'

unable to register delegated type (memory allocation failed)

unable to set global value 'string'

unable to set value of object 'string' property 'string'

Unable to update topology for switching action

Unconnected node - 'string' id:'integer'

undefined pass type for add breakpoint

Unexpected link current update call from 'string'

Unknown exception in pw_recorder::build_keys()!

unnamed command syntax error

vfd:'integer' 'string' -- failed to allocate dynamic array

vfd:'integer' 'string' -- the stable_time value must result in at least 1 timestep of averaging!

violation_recorder::flush_line(): output file is not open

violation_recorder::flush_line(): unable to flush output file

violation_recorder::write_footer(): output file is not open

violation_recorder::write_line(): error when converting the sync time

violation_recorder::write_line(): error when writing the sync time as a string

violation_recorder::write_line(): error when writing to the output file

violation_recorder::write_line(): no output file open and state is 'open'

Water heater line voltage for waterheater:'integer' is too high, exceeds twice nominal voltage.

watertank thermostat is set to 'real' and is outside the bounds of 90 to 160 degrees Fahrenheit (32.2 - 71.1 Celsius).

watertank volume of 'real' outside the volume bounds of 20 to 100 gallons.

weather property refers to a(n) \


Warnings | Errors | Fatal errors | Exceptions

Fatal errors

' B D E I M N O P R S U X

'string' environment not recognized or supported

Breaking an infinite loop in local_datetime! (ts = %

Breaking an infinite loop in local_datetime_delta! (ts = %

default redirection of 'string' failed: 'string'

definition is missing

environment not specified

environment startup failed: 'string'

incorrect module list file name

info subject not specified

insufficient buffer space to compile init code (inline_block_size='integer')

intrinsic 'string' is not defined in class 'string'

missing library name

missing output file

missing server ip address

missing server port number

missing thread count

module 'string' does not implement a test routine

module 'string' is not found

module list not specified

no filename for testall

object_sync(OBJECT *obj='string', TIMESTAMP ts='string', PASSCONFIG pass='string'): int64 sync_'string'(OBJECT*,TIMESTAMP,PASSCONFIG) is not implemented in module 'string'

ordinal 'integer' is too small (first is 'integer')

processor number not specified

property_type[] in class.c has an incorrect number of members ('integer' vs 'integer')

redirection is missing

redirection of 'string' to 'string' failed: 'string'

redirection of all failed

shutdown after command line rejected

shutdown after simulation stopped prematurely

unable to create pidfile 'string'

Unable to find class 'string' in module 'string'

unable to grow index 'integer': 'string'

unable to open 'string' for writing

Unable to store module name

unable to write to 'string'

unexpected branch result in object_tree_delete

xml encoding not specified


Warnings | Errors | Fatal errors | Exceptions

Exceptions

' - _ A C E F G I K L N O P R S U

'string'('integer'): 'character' is not recognized at 'string'

'string'('integer'): ^ not allowed after 'character' at 'string'

'string'('integer'): constant 'character' is not valid

'string'('integer'): constant definition of 'string' failed; unit already defined

'string'('integer'): derived definition of 'string' failed; unit already defined

'string'('integer'): memory allocation failed

'string'('integer'): primary definition of 'string' failed; unit already defined with a different parameter set

'string'('integer'): scalar definitinon of 'string' failed: 'string'

'string'('integer'): syntax error at 'string', exponent must be greater than 1

'string'('integer'): unable to find or derive unit 'string'

'string'('integer'): unable to read unit 'string'

'string'('integer'): unit 'string' is not recognized

--modhelp: malloc failure

_random_specs(type='integer',...); type is not valid

_random_value(type='integer',...); type is not valid

A non-positive value has been specified for within.

class_add_extended_property(oclass='string', name='string', ...): memory allocation failed

class_add_extended_property(oclass='string', name='string', ...): property type is invalid

class_add_extended_property(oclass='string', name='string', ...): unit 'string' is not found

class_get_first_property(CLASS *oclass=NULL): oclass is NULL

error when setting parent

forecast_create(): memory allocation failed

forecast_save(): memory allocation failed

global_create(char *name='string',...): property extension code not recognized (PROPERTYTYPE='integer')

global_create(char *name='string',...): property keyword could not be stored

global_create(char *name='string',...): property name 'string' is too big to store

global_create(char *name='string',...): property size must be greater than 0 to allocate memory

global_create(char *name='string',...): unable to allocate memory for global variable

global_create(char *name='string',...): unrecognized property access code (PROPERTYACCESS='integer')

invalid line configuration for overhead line

invalid line configuration for underground line

invalid or missing line spacing on overhead line

invalid or missing line spacing on underground line

invalid regulator configuration

invalid regulator type

kml_dump(char *filename='string'): 'string'

kurtosis aggregation is not implemented

link from node is not specified

link from reference not a node

link to node is not specified

negative fault impedance is invalid

negative maximum_voltage_error is invalid

no overhead line configuration specified.

no regulator configuration specified.

no underground line configuration specified.

nominal_voltage is not set

object 'string' commit failed

object_close_namespace(): no current namespace to close

object_create_foreign(OBJECT *obj=): obj->oclass is not really a class

object_create_foreign(OBJECT *obj=): object->oclass is NULL

object_create_foreign(OBJECT *obj=NULL): object is NULL

object_create_single(CLASS *oclass='string'): abstract class 'string' cannot be instantiated

object_create_single(CLASS *oclass='string'): memory allocation failed

object_create_single(CLASS *oclass=NULL): class is NULL

object_dump(char *buffer=%x, int size='integer', OBJECT *obj='string':'integer') buffer overrun

object_open_namespace(char *space='string'): memory allocation failure

print_class_d: tabdepth > 32, which is mightily deep!

property 'string' not found in object 'string'

property_malloc(oclass='string',...): property 'string' unit 'string' is not recognized

random_exponential(l='real'): l must be greater than 0

random_pareto(m='real', k='real'): k must be greater than 1

random_sampled(n='integer',...): n must be a positive number

random_weibull(l='real', k='real'): k must be greater than 0

raw unit 'string' was not found

Regulator connect type not supported yet

schedule_read(SCHEDULE *schedule={name='string',...}, TIMESTAMP ts=%

skewness aggregation is not implemented

Switch from node is not specified

unable to register class lights

unable to register class pw_load

unexpected motor state

unitfile: 'string'

unknown microwave state

unknown regulator connect type

unknown transformer connect type